The high limit thermostat is a safety thermostat that cuts the heating elements in the event that they become too hot. Note: This video is intended to give you … If you are not sure which part is causing your dryer to not heat, please contact us today to schedule a repair to appoint with one of our highly trained technicians. Unfortunately, a non-heating dryer can also be caused by a faulty thermal fuse, a defective igniter, or a damaged flame sensor. In GE dryers, the thermal fuse--sometimes called a safety thermostat--is located behind the drum on the inside of the dryer. Now you can reinstall the dryer’s front panel. Unplug the dryer… It is approximately 2 inches wide from tip to tip. To make sure your repair was successful, throw a batch of wet clothes into your dryer and start it up. Once the panel is aligned properly, reattach the screws that hold the cabinet and panel together. We also have installation guides, diagrams and manuals to help you along the way! Remember to take note of which wire is connected in the front and which is connected in the back of the high limit thermostat. Before repairing your dryer, unplug the appliance from the wall socket or switch off the electricity at the circuit breaker. Doing so, creates slack in the belt. The high limit rear area of the blower housing. Now stand up and use the belt to help guide the drum through the front of the dryer. 3977393 Dryer Thermal Fuse & 3392519 Thermal Fuse & 3977767 Dryer High Limit Thermostat & 3387134 Dryer Cycling Thermostat - Replacement Part for Whirlpool Kenmore Dryer 2.0 out of 5 stars … Set your ohmmeter at its lowest scale and confirm that it is closed by measuring less than 1 ohm. The operating thermostat is in series with the heater element. Start by taking out the screws on the back of the control panel. This can happen if the dryer vent is blocked and the dryer can't get rid of the hot moist air from the drum. 4. Make sure the shaft at the back of the drum is aligned with the opening in the rear wall of the cabinet. With the screws out, reach between the drum and the support panel to push down on the idler pulley. Rest the front of the console on the back of the dryer. The thermostat is out of stock wherever I check Rack dry thermostat … Operating thermostats control the temperature of the air inside the drum. Thermostats open and close an internal switch with respect to the temperature of their environment. The new limit thermostats have a plastic base to make them react slower to rapid changes in temperature. GE WE4M137 Genuine OEM High Limit Thermostat for GE Dryer 4.4 out of 5 stars 107. Once there is enough slack, unthread the belt from the pulley and the motor shaft. Someone also told me it could be dryer … If a thermostat is not charred and it is closed it is usually OK. GE Replacement High Limit Thermostat For Dryer, Part# WE04X26139. I have replaced it 4 different times and replaced the thermistor the last time. No liability is assumed by the author for the accuracy of the contents or damages caused by the use of these procedures. GE Dryer High Limit Thermostat. Now you can reattach the belt by inserting your arm underneath the drum. This is most likely caused by the dryer vent being stopped up, so if the high limit … Click the banner to visit our sponsor to purchase parts: All of the information in these Appliance Clinic procedures is provided FREE OF CHARGE. DBL333 dryer pdf manual download. Take all suspect thermostats to your nearest appliance store to purchase new ones. I have an LG dryer where the high limit thermostat continually blows. Once the part is secure, connect the wires to the thermostat. Once the top panel is secure, open the dryer door and reinsert the screw that secures the top panel to the front panel. Thermal fuses burn out to prevent fires. Genuine OEM Part # WE4M137 | RC Item # 276438. As its name implies, this thermostat shuts off the heater element if a dangerously high temperature is reached. Once the wires are removed, take out the mounting screw that secures the thermostat to the heating duct. I am not sure which would be considered thermal fuse. Saturday: 9:00am – 3:00pm, The high limit thermostat in your GE dryer model. After the wires are in place, you can start putting your appliance make together. Make sure to firmly push the wires into place; otherwise, you will end up with a poor connection, meaning you’ll be forced to disassemble your dryer and fix the problem once again. The high limit monitors the dryer temperature and shuts off the heating element if the dryer overheats. … If the … Reinsert the screws that hold the side of the cabinets to the support panel. When the temperature in your dryer reaches 250 to 300 degrees Fahrenheit, depending on the part, the high limit thermostat is triggered, meaning it turns off the heat in your appliance. The limit thermostat is located on top of the heater shroud. Sometimes these are #15 Torx. This part is the replacement high-limit thermostat, or simply the thermostat for your dryer. In addition, the dryer may have a thermometer and temperature control or a simple thermostat. The hi-limit thermostat is a fairly reliable dryer component and is rarely the cause of dryer heating problems. Stand up and rotate the drum to help align the belt. Once the screws are out, lift up the front of the console to unfasten the three tabs that lock into the top panel. With the top off the dryer, uninstall the screws that hold the front panel to the cabinet. Replace a charred thermostat if the ohmmeter shows an open circuit at room temperature. Dryer Will Not Run or Start. Now that you can see the wires running to the door switch, disconnect them. Privacy Policy - Conditions of Use - Infringement Policy, Monday – Friday: 7:30am – 5:30pm  Now it is time to take out the dryer drum. There are two different thermostats in your dryer: the operating thermostat(s) and the limit thermostat. Where is the thermal fuse located on kenmore model 110 electric dryer - Answered by a verified Appliance Technician We use cookies to give you the best possible experience on our website. Once the front panel is free of all connections, lift it off the cabinet and place it somewhere safe. View and Download GE DBL333 technical service manual online. To do so, remove the screws securing the sides of the cabinet to the support panel. HIGH LIMIT THERMOSAT. Open the door and remove the 2 screws on the backside of the thermostat housing. You’ll find the thermostat mounted on the back, right-hand side of your appliance. Skill Level ... this high-limit thermostat will cut off the power to the heating element. Start the reassembly process by reinstalling the dryer drum. Sometimes the screws are #15 Torx. Would it be safety thermostat part number we4m160 or hi limit thermostat part number we4m137? Line the panel up with the mounting brackets on the base of the dryer. Visually inspect the operating thermostat. Once the drum is in place, let go of the belt. They will usually get very hot before they weld and char the paper label. … However, a thermostat's contacts can weld together and pass this test. If replacing your dryer’s high limit thermostat did not correct your appliance’s heating problem, another part in your dryer may be malfunctioning. If your dryer will not run or start, check the following: Make sure the dryer plug is pushed completely into the wall outlet. Use the belt at the top of the drum to help guide the part into the front of the cabinet. $6.48 Ships within 2 Days − + Add ... General Electric Replacement High-Limit Thermostat For Dryer, Part # WE4X584. This video provides step-by-step instructions for replacing the rear high-limit thermostat on LG and Kenmore electric dryers. Genuine OEM Part # WE11X20397 | RC Item # 3387282 ... 365 Day Return Policy Retail Location … There is a "standard " thermostat 6 inches away from the high limit thermostat … The operating thermostat normally opens from 120 to 170 degrees and is always closed at room temperature. You have now gained access to the high limit thermostat in your GE dryer. Only 15 left in stock - order soon. Dryer High-Limit Thermostat WE4M137 parts - manufacturer-approved parts for a proper fit every time! If the dryer will not start there are a few things you can check to see if you are able to correct the situation. The thermostat is designed to shut … Pull the defective high limit thermostat out of your dryer. Once you make contact with the belt and idler pulley, push down on the pulley and thread the belt onto it and onto the motor shaft. How to Replace Broken Glass on a Glass-Top Stove, Where to Find Your Whirlpool Electric Range Serial Number. LARGE CAPACITY DRYERS. There is also a difference between a thermostat and a thermistor. Thermal Cut-Off: The dryer's thermal cut-off is similar to the thermal fuse and the high limit thermostat… unlocking this staff-researched answer. The only difference in these thermostats is their opening and closing temperatures. This is done to encourage you to fix the problem. Now that your dryer has a brand new high limit thermostat installed, plug the appliance back in or turn it back on at the circuit breaker. In order to reach the high limit thermostat, you must disassemble your dryer. The only difference in these thermostats is their opening and closing temperatures. General Electric WE4M181 Dryer Cycling Thermostat 4.6 out of 5 stars 70. This can happen if the dryer vent is … As its name implies, this thermostat shuts off the heater element if a dangerously high temperature is reached. Learn how your appliance is supposed to operate so you can determine if it is malfunctioning. Then the electricity will no longer flow to the heating element and your clothes will need more time to dry. All dryers have a high limit safety thermostat that cuts power to the element at a lower temperature than the thermal fuse burnout temperature. After the screws are out, close the dryer door and lift the top panel off the appliance. Under normal conditions, the dryer's primary operating thermostat will cycle the heater on and off to prevent temperatures from rising too high within the dryer. Wearing protective gear, such as, safety goggles and work gloves are highly recommended during any type of do-it-yourself appliance repair. The high-limit thermostat cuts power when the temperature reaches a higher limit. The flame will only stay lit for around 5-10 seconds and then it goes out for about 30 seconds. Test a high limit thermostat with an ohmmeter. Reattach the front of the console by lining up the tabs at the bottom with the slots on the top of the dryer. Page 40: Outlet Control Backup Thermostat High Limit Thermostat Outlet Control Thermistor The high limit thermostat is located on the top The outlet control thermistor is located on the lower right area of the heater housing. The center, rectangular portion of the thermostat is approximately 1 inch in width and a little more than 1 inch in length. Replace the thermostats (you can reverse the wiring on a two-terminal thermostat with no ill effects). The high limit thermostat can be found in gas and electric dryers and serves as a safety feature that helps to prevent the dryer from becoming too hot when it's running. How to Replace High-Limit Thermostat #WE4M137 Step by step instructions on how to replace a High-Limit Thermostat #WE4M137 for Dryer made by GE, Kenmore. Home Page > Troubleshooting and Repair > GE Electric Dryer > Thermostats. Support wikiHow by With the front panel reconnected, it is time to attach the top panel. Though it may sound a bit daunting, opening the top of the dryer … Before you can remove the front panel, you have to disconnect the door switch harness. Home All Parts GE Parts GE Washer Dryer Combo Parts GE Washer Dryer Combo Fuse, Thermal Fuse, Thermostat… $37.39. If the vent hose or vent become blocked, the heat from the elements without airflow will open the high limit thermostat. Check that the dryer … If the paper labels are charred and illegible, remember whether they were operating thermostats or the limit thermostat. Does the paper label or terminals look charred? Thermostat Operation The operation of a dryer thermostat is not difficult to understand. 417.94712400? $35.99 … Proper Operation It is below the thermostat … To do so, simply align the tabs on the panel with the slots on the frame and carefully lower the top down. Make sure you can feel the air blowing through the outside vent first. An L155 thermostat will open at 155 degrees F. You need to raise the top of the dryer to access the high limit thermostat. The temperature of the air inside the drum is regulated using thermostats. There are two different thermostats in your dryer, the operating thermostat(s) and the high limit ( safety ) thermostat(s). Disconnecting the vent will do nothing electrical or mechanical for the machine. Before reattaching the belt to the pulley and motor shaft, make sure the belt’s ribbed side is facing down and the smooth side is facing up. Test: Disconnect all connecting wires and check for continuity across the hi-limit thermostat or sensor set. Keeping the thermostat … If it shows 0 ohms at room temperature, it's OK but if you see an open circuit (infinite impedance), replace it. Lift the top up and look for the limit thermostat on the top of the heater element shroud in the back behind the drum. To install the new high limit thermostat, attach it to the heating duct and reinsert the mounting screw. Buy only new GE replacement parts for the limit thermostats. The limit thermostat opens at its rated temperature but does not close again when the temperature goes down and therefore must be replaced. Push the front of the console onto the back of the console attach reattach the screws you took out earlier. To access the thermal fuse you will need to open the dryer from the top. The operating thermostat is mounted just behind the lint filter and down under the door. Open up the dryer door and remove the screws inside the door frame that secure the front panel to the top panel. Remove the 4 screws securing the cabinet top in the front. The thermostat's operating temperature (temp that it will open) is stamped on its base. If the high-limit thermostat has blown, the dryer won't... GE Dryer Heating Element. Make sure the wires are secure before you lift up the drum to snap the front panel into place. To remove the faulty part, disconnect the two wires running to the thermostat. I have a GE gtdp220ef3ww clothes dryer. If either does, replace the thermostat. Lean the front panel back a few inches and reach down to disengage the shield protecting the wires. The rising temperature inside the dryer will make the top of the dryer feel hot and it will also usually trip the high limit thermostat. I have a Maytag LDG7334AAE gas dryer. The limit thermostat is located on top of the heater shroud. The high limit thermostat functions as a safety device that prevents the dishwasher from getting too hot. If it is malfunctioning, it might be shutting off the heat before your dishes are finished drying. Raise the panel up a little bit and reconnect the wires to the door switch. I bypassed the high limit thermostat to see what would happen and the flame stayed on. The high limit thermostat can cause GE dryers not to heat. This keeps cycling causing a slow dry time. The operating thermostat is down under the lint filter in the front panel.